Set design, development, production, production and sales services as one of the diversified enterprises, the original high-end motor protector, successful research and development of intelligent integrated motor protector, motor protector, microcomputer protector, power meters, switchgear intelligent control device, service robot and other products.

GY800 motor protection device

  • GY800 motor protection device Product Introduction GY800 motor protection device is indispensable protection device for the motor industry and the modern economy development, It is made by wide temperature and low power consumption 16 bit i
  • support hotline:13732088722
  • Product Details

  GY800 motor protection device

  

  Product Introduction

  GY800 motor protection device is indispensable protection device for the motor industry and the modern economy development, It is made by wide temperature and low power consumption 16 bit industrial smart integrated circuit, independent property right and software copyright. It can do the collection, calculation,analysis, measure &control,protection, alarming,monitor and interlock of the motor signal while the motor is functioning. Its use has almost penetrated into all fields and industries. It is an effective safety guarantee for the normal operation of three-phase motors used in industry, agriculture, national defense construction and people’s daily life. Therefore, it is of great significance to save energy, improve production efficiency , economic benefit and ensure safe production.

  The new generation of intelligence has the functions of electricity calculation,accident analysis , motor error reporting and so on in addtion to conventional low-voltage motor protection, monitoring, control functions. Using the motor protect and control system to improve company’s reliability and safety will improve the company’s automatic management level for the functioning motors. GY800 motor protection device uses the LCD screen to display all the functioning motor’s datas like three-phase voltage,three-phase current,power factor,each time/total electricity,rate,power,error message,alarming value,total operating time and so on to complete the remote automatic control,direct control ,terminal control,forward and reverse stratup control,star triangle startup control,auto step-down control,direct bypass control to the motor。Its fieldbus RS5485 interfaces support various protocols which can be used in many microcomputer industrial control configuration software to complete the network communication management,on the other hand, it can also connect with the DCS system by the way of 4-20 Ma variable signal output, then transmit and output the operating parameters of the motor to form a distributed integrated electric power monitoring system to carry out a variety of control such as remote measurement&control,remote communication, remote control, protection, setting. GY800 motor protection device is designed with software,hardware and EMC self-calibration function, and has super anti-interference ability and the reliability of accurate and sensitive action.Its size is small and its structure is compact,so it can be straightly installed in Low voltage control terminal cabinet and each kind of 1/4 and above drawers by screw or lead rail,it is especially fit for scientific and effective industrial level protection and measure&protect module .

  Function Summary

 

 

 

 

 

Protection

Function

Basic Functions

Standard

Match

Remark

overvoltage protection

 

fuction after alarmed 3 seconds

undervoltage protection

 

fuction after alarmed 3 seconds“0”stop fuction

overload protection

 

current value&function time settable

underload protection

 

locked-rotor protection

 

multiples of locked-rotor settable

open-phase protection

 

fuction after alarmed 3 seconds

leakage protection

 

set the value of the leakage current

timeout protection

 

start time delay setting according to the equipment need

reversal protection

 

function by automatic judgement

feeder protection

 

electric shock protection

 

Automatic recovery within three seconds

external fault protection

 

function by automatic judgement

electric delay protection

 

delay time settable

 

Control

Function

direct start-up

 

 

select wiring according to the start mode,

set the change-over time and start mode

star triangulation start

 

direct bypass start

 

forward and reverse start

 

step-down start

 

Fault Reset

manual reset

 

time automatic reset or “0” shutoff to  manual reset are selectable

automatic reset

 

Control Authority

front-panel control

 

set the control and protection rights

remote terminal control

 

fieldbus control

 

Measure Function

three-phase current

 

monitor module

three-phase voltage

 

leakage current

 

rate power

 

power factor  apparent power

 

elctricity

 

Communication Function

RS485interfaces/ Mdobus-RTU

 

protocol

Analog Output

One channel DC4-20mA

 

internal DC24V power supply

Switch Output

6-channel optoelectronic

barrier input,function editable

 

Control Output

6-channel relay output,

function editable

 

rivet capacity 5A

Set Reminding

full screen English

 

LCD display

Fault Query

last ten fault query

 

Time Query

Accumulated or current time function time query

 

Parameter Query

function, set-up, fault message electric power, rate, apparent power

 

 

   Technical Parameter
  

Work power

AC/DC 85~265V  50Hz

Power supply circuit voltage

≤AC1160

Control the relay output

passive contact  5A

Install mode

standard 35mm lead rail installation or screw fix

Field of application

three-phase power supply equipment

Overvoltage protection

set the voltage value

110~465 V settable

Undervoltage protection

set the voltage value

0~380V settable

Overload protection

current setting

A settable within standard current

function time

1~255S settable

Underload protection

current setting

A settable within standard current

function time

0~255S settable

Open-phase protection

percentage setting

1~100% settable

Leakage protection

leakage current value setting

50~5000mA settable

function controlled by programming

Locked-rotor protection

multiples setting

1~9 multiples settable

Timeout protection

start delay time setting

1~255S settable

Fault reset

manual reset

be“0”

automatic reset

0~255S settable

20mA corresponding current

set 20mA corresponding current value output

Communication address

The device communication address

1~255 machine settable

Start type

select start type

direct startup, star triangle startup,forward and reverse startup, direct bypass,forward and reverse bypass startup,step-down startup settable

Relay transfer time

transfer time

1~250S settable

Programmable relay style

startup delay closeleakage delay closefault shutdown closepower on delay closealarming delay close setablelow power factor alarming closed

Programmable relay output time

output delay time

1~250S settable

Overload control protection

when the motor is overload,the over current will be calculated according to the motor heat capacity tracking.Fully considered the motor rotor and stator’s temperature rise and the influence to the motor heating because of the three-phase unbalance.When the current reached the control protection value,the device will do the alarming and notice the shutdown delay time.

Underload protection

when any one of the three-phase current is lower than the set underload value,the device will do the alarming and notice the shutdown delay time.

Locked-rotor protection

when the current value reached the set current multiples,the protection device will do the alarming and notice the shutdown delay time.

Three-phase current unbalance protection

when the ratio of the minimum phase or the maximum line current reaches or exceeds the set value, the protection device will do the alarming and notice the shutdown delay time.

Open-phase protection

It will be judged as open-phase fault if any one of the three-phase current’s ratio is not bigger than the unbalanced angle value, the device will do the alarming and notice the shutdown delay time.

Overvoltage protection

The protection device and the measure device monitor the three-phase voltage value, the device will do the alarming and notice the shutdown delay time if the equipment’s largest voltage is higher than the set value.

Undervoltage protection

The protection device and the measure device monitor the three-phase voltage value, the device will do the alarming and notice the shutdown delay time if the equipment’s smallest voltage is lower than the set value.

Leakage (earth)protection

Judge the leakage fault by using the zero sequence current transformer to measure the protective conductorPEor PEN’s short-circuit leakage current value.When the short-circuit leakage current value is bigger than the set leakage value, the device will do the alarming and notice the shutdown delay time.

Electric shock protection

The protection device monitors the equipment’s voltage continuously, when the system voltage recovered after the moment dropped,the motor can start again.

Timeout protection

The protection device inspects the start-up current delay time,when the equipment can bot be started up within the start-up delay time,and the three –phase current is 1.2 time bigger than set current,the timeout protection will function and the power will turn off.

Reversal protection

When the protection device monitored the three-phase voltage sequence is not correct,the equipment can not start-up.

External fault protection

When the device monitored the external switching value input signal is different from the device’s set switching value input signal,the device can not be started up.

  Current specification

  

Model

Power range

Current range

remark

6.3A

0.55Kw-3.7Kw

0.5A-6.3A

 

 

Wring through the protection device CT hole directly

20A

3 Kw-12 Kw

5A-20A

63A

10 Kw-30 Kw

10A-63A

100A

20 Kw-50 Kw

20A-100A

150A

37 Kw-90 Kw

40A-160A

300/5A

75 Kw-132 Kw

50A-300A

 

 

Provide 3 pieces of turns ratio standard current tranformers

400/5A

90 Kw-200 Kw

70A-400A

600/5A

110 Kw-300 Kw

100A-600A

800/5A

155 Kw-400 Kw

150A-800A

1000/5A

220 Kw-450 Kw

250A-1000A

1500/5A

450 Kw-750 Kw

400A-1500A


  Terminal definition(The terminal’s maximum linwidth is 1.5mm )

Terminal NO.

Instruction

1…2

Device working power AC/DC 220V input

5…7

A/B/C three-phase voltage input

4

N neutral point input

35…36

Relay control J1

33…34

Relay control J2

31…32

Relay control J3

29…30

Protect the output relay J4 closing

28…29

Protect the output relay J4 opening

26…27

Programmable relay output J5

21…22

Zero-sequence current input

3

Authority control or external fault

15…16

4-20mA output15 is -  16 is +

8

SDS stop input

9

DCS start1 input

10

DCS start2 input

11…13

Equipment feedback  input

14

DC24V output value driveOnly for this device

23…24

RS485 communication interface23isTA  24isTB

25

Device is earth

18…20

|A-18/|B-19/|C-20Three-phase current input

17

secondary current input common terminal


  Typical wiring

  

  Installation size

  

  

 

  Forward and reverse start control

  In this mode,The device controls the relay 1 to make the motor forward and the relay 2 to make the motor backward.When the device received stop command or any protection action,it will transmit the stop command to the relay 1 and relay 2 to stop the motor function.

  

  Direct start control

  Direct start is the equipment’s basic start type.When the device received the fieldbus or“I/O” start signal, output relay’s contact point will control the 1 closed.When the device received stop or any protection signal,the contact point will control the 1 opened.

  

  Direct bypass start control

  When the device received the fieldbus or “I/O” start signal,the output control relay 1 will output a pulse closing signal.When the device received the stop or any protection signal,the output control relay 3 will output a pulse closing signal to open the direct bypass start mode,the operation screen will not work soon, and can start or stop the motor through the external button.

  

  Star-triangle start control

  The equipment is in star shape wiring before be started, When the start current is below 1/3 of the triangle shape wiring’s current and the start torque is also below 1/3 of the triangle shape wiring’s torque,the equipment will begin the star step-down start and will do the star-triangle transformation if reached the transformation time,Then it will function in triangle wiring mode.

  Need to follow the principles when setting parameters:change-over time(start time,the star -triangle transformation must be completed before the equipment is started up).

  

  Autotransformer step-down start control

  As the name implies, the equipment is started through the autotansformer step-down.The reduction of the start voltage aims at reducing the start current,and the start torque will also reduce at the same time.

  Need to follow the principles when setting parameters:change-over time(start time,the transformation must be completed before the equipment is started up).

  

Geyao Building, the Junction of Shanhai Road&Haixia Road, Industrial District, Cangnan County, Zhejiang Province
0577-59921168
cngydz@163.com
WeChat

Ge Yao Technology provides high-quality products like the society to meet the full range of customers' needs. No matter where the motor protector products are sold, we have our sincere service outlets.

Site map